Launch abort.
If for any reason the decision is made to abort the launch after the countdown has started, proceed as follows:
- Engine prime switch [56, fig. 5-1] – STOP PRIME.
- Igniter idle switch [53, fig. 5-1] – Check OFF.
- Engine precool switch [61, fig. 5-1] – OFF.
- Engine master switch [63, fig. 5-1] – OFF.
- Vent, pressurize, and jettison control lever [11, fig. 5-4] – VENT.
- External power switch [22, fig. 5-3] on the service panel – ON. Electrical power will be supplied from an external source.
- No.1 and No. 2 generator switches [21, 26, fig. 5-1] – OFF. Check that both No. 1 and No. 2 generator-off (amber) lights [20, 25, fig. 5-1] come ON.
- APU switches [17, 30, fig. 5-1] – OFF.
- Ventral arming switch [35, fig. 5-1] – DE-ARM.